67 CORROSION OF MILD STEEL IN OPC / RHA MORTARS By S. E. Benjamin1 and Wajjid Ali Shah2 ABSTARCT The effect of Rice Husk Ash (RHA) additions on the corrosion of mild steel in the concrete in contaminated Ordinary Portland Cement (OPC) mortars was studied. The corrosion potential of steel embedded in mortar mixes with different OPC / aggregate ratios with partial replacement of OPC with RHA containing different levels of chloride was monitored during the hydration period only. The chloride is taken as an admixture and added with the mix water. It is observed that RHA is beneficial in mitigation of corrosion when present with a reasonable amount of OPC. Low OPC mortars containing chloride ions show corrosion irrespective of the RHA content. INTRODUCTION The corrosion of steel in concrete is due to electrochemical processes in the presence of conductive medium, which in case of concrete, is supplied by the water present inside the porous network. Therefore, charge transfer reactions are possible at the interface between the ions in the electrolytic medium and the embedded steel. The cement coating is a good barrier and it also furnishes hydroxyl ions 1-2 in the pore environment that makes the steel passive. The passivi ty of steel is destroyed when the critical Cl- / OH- ratio exceeds a certain limit 3. It has been observed that if the relative humidity is less than 40%, then corrosion risks, especially due to chlorides4 become negligible5. The role of other materials as partial replacement in ordinary Portland cement (OPC) have been explored to reduce the costs and to mitigate corrosion. Pozzolans as fly ash 6 have been found effective in reducing corrosion rates due to chloride in admixture. However, chloride as an admixture can be only fought against by reasonable amounts of ordinary OPC in the blend to initiate the pozzolanic activity and to furnish OH- ions for the required passivity of steel. Rice Husk (RH) is also being investigated as a partial replacement material for OPC. RH occupies an important position among agro-industrial wastes, and its silica content is highest among all of them. It is widely available in rice producing countries. RH Pakistan produces about 4 million tons of paddy every year from whic h 0.8 million tons of RH are separated as by- product. Such huge amounts are not utilized properly and common practice is to burn out the RH which is a wasteful exercise 7. Heap burning of RH causes pollution hazards for surrounding population and has disposal problems also. Rice Husk Ash (RHA) can be made from burning of rice husk under controlled conditions of temperature. The main constituent of RHA is SiO2, which constitutes about 80-90% of the material. It is present in the original rice husk in the form of hydrated silica and gets converted into amorphous silica at burning temperatures of 400-600 °C. The burning temperatures and time of burning are critically important as these affect the specific surface area and the reactivity of RHA8. The ash may also contain a few percent of K 2O and Na 2O and up to 20% of residual carbon. OPC / RHA blends have been found to be successful in imparting compressive strength to concrete due to reduction in porosity9 and hence it is expected that it will also control ingress of chloride from outside to the embedded steel surface. Previous studies have likewise mainly focused on the diffusion of chloride ions into the cement matrix. In such cases RHA has been established as a good substitute for OPC in portion [10-11]. Also, when mixed with lime in certain _____________________________________________________________________________________________ 1. Professor, Department of Chemistry, Forman Christ ian College – A Chartered University, Gulberg-II, Lahore, Pakistan 2. Principal Scientific Officer, Glass and Ceramics, Pakistan Counc il of Scientific and Industrial Re search, Lahore. Pakistan. 68 ratio (commonly 1:2, lime : RHA), it finds wide applications to produce concrete blocks, well rings flooring and road sub-bases[12]. The present investigations were conducted with an objective to study the behavior of OPC/sand mortars with different RHA replacements for OPC when chloride ion is already present in the mix. The free corrosion potential (Ecorr) of the samples were measured during the entire hydration period to study the effect of RHA additions to the cement mortars. EXPERIMENTAL Rice Husk (RH) was brought from the Anmol Rice Mills, Sehjoke (8 Km from Daska, Sialkot). Almost 2 kg RH was taken in a large tub. It was washed with tap water in order to remove the small particles and impurities from it. This process was performed repeatedly for almost fifteen days. To remove more impurities, almost 200 g of RH was taken separately in two different washing solutions. Washing of RH was done by two methods as follows: (a) Method 1: RH was washed using H2SO4/HNO3 (1:1). (b) Method 2: RH was washed using H2O/H2SO4/HNO3 (2:1:1) After several washings by both the methods, for over a month, RH was dried in air first and then in an oven for 10 minutes at 100 °C and put in the desiccators for 28 hours. The dried RH was taken in a large pre-weighed ceramic crucible. It was placed in an electric furnace at 500 °C for 5 hours. Rice Hask Ash (RHA) was produced. The effect of time of burning was also studied on RHA by burning RHA for one hour before burning in the electric furnace for two hours at 500°C. The results are given in Table-1. Washing Solutions Wt. of RH taken in washing soln. Wt. of RH after washing and drying Wt. of fully dried RH Wt. of RH taken in the crucible Temperature (°C) Time (hours) Wt. of RHA formed 1 200g 72.2987g 70.2016g 43.3706g 500 5 4.48g 2 200g 74.3350g 70.5039g 44.5675g 500 5 4.73g 1 100g 50.9217g 49.6923g 49.6923g 500 3* 6.90g 2 100g 52.5609g 51.0302g 51.0302g 500 3* 6.89g * one hour burning of RH in gas furnace + 2 hours in the electric furnace = 3 hours burning time Table-1. Amount of RHA obtained with washing solutions 1 and 2 The results show that the washing solution composition does not affect the amount of RHA obtained. However, the time of burning influences the weight of RHA gained i.e, less RHA is obtained when the RH is burnt for longer time period i.e., 5 hours as compared to 3 hours. The specimens were made from ordinary mild steel, courtesy Black Gold industry, Bund Road link, Bogiwal Road, Lahore. The steel was Model steel grade-40. The steel bars was made to size on lathe machine and then cut into cylindrical shape of about half an inch in size. The steel samples were roughly grinded to have a uniform and clean surface. These were threaded on one side to tightly attach an iron rod for a sound connection. The density, surface area and diameter of each sample was measured and recorded. The bottom of the sample (the area to be exposed for test) was polished by emery paper of various numbers, starting from 100 till 600. A PVC pipe was cut in pieces larger than the size of steel sample. The steel sample was placed inside it and then mounted using cold mounting technique. The epoxy used for this purpose was Magic Depoxy Steel (filler made in Pakistan stock no. DS 400) and mixed with hardner. The epoxy completely covered the gap between the 69 pipe and the steel specimen. These samples were then left undisturbed for about 24 hours so that the epoxy hardens and bonds well with the sample and the covering pipe. The exposed area of the specimen for the corrosion studies fell in the range 0.78 – 0.85 cm 2. The polished bottom end was then washed with alcohol and dried with a tissue paper and covered with paper tape till the time of test. This is a safety precaution to ensure the removal of any unnecessary epoxy that gets on to the surface of the specimen. Furthermore, it has been proved that polished samples show more resistance to corrosion[13]. The prepared steel specimen were cast into OPC mortars by placing the specimen inside a larger PVC pipe and filling the gap between the specimen and the PVC pipe inner boundary with epoxy so that half an inch space is left. It is hardened and then filled with OPC mortars with different OPC/sand ratios, RHA and different admixtures. The mortar samples were allowed to set for 24 hours. The samples were then stored in polythene bags to avoid further contact with atmospheric moisture to preserve the polished bottom surface. Concrete mortars were prepared with different admixtures such as RHA, sand, and NaCl. The sand was taken from River Ravi near Bakkarmandi, and washed several times to remove the impurities. It was dried well before using in the concrete mortars. The chemical composition of the cement used, courtesy CRI, Tusdec, Lahore, is given below in Table 2. SiO2 Al 2O3 Fe 2O3 CaO MgO SO 3 Loss On Ignition (LOI) Insoluble Residue 20.34 4.9 4.14 62.05 1.59 2.65 2.72 0.36 Table-2. Chemical analysis (wt. %) of OPC cement Sample Mortar samples were prepared of different composition of OPC : sand : RHA : NaCl. The water: cement ratio was fixed at 0.5 and NaCl was added in the mix water. Different sets of mortars prepared are as follows: Set 1 : OPC : Sand : RHA (% by wt. of OPC) : NaCl (% by wt. of OPC) a) 1:1:0:0 b) 1:3:0:0 Set 2 : OPC : Sand : RHA (% by wt. of OPC) : NaCl (% by wt. of OPC) a) 1:1:10:1 b) 1:1:20:1 c) 1:1:30:1 Set 3 : OPC : Sand : RHA (% by wt. of OPC) : NaCl (% by wt. of OPC) a) 1:1:20:1 b) 1:3:20:1 These mortar samples were placed in 30 ml distilled water for hydration in individual beakers after 24 hours of casting. After 1-day their Ecorr values were measured against standard calomel electrode with the help of multimeter (DT-830B). 70 RESULTS AND DISCUSSION The present investigations were conducted to study the effect of addition of RHA upon the corrosion performance of embedded steel in OPC sand mortars with different levels of chloride both in good and poor mixes. The RHA , which is a waste material (obtained from burning of the RH) that can be used as a replacement material in place of OPC. It is reported that RHA aids in OPC hydration [14] and thus provides low porosity and more strength [15]. RHA was prepared by washing, followed by drying and burning the RH at fixed temperatures. It is observed that RHA formed is not affected by the composition of the washing solution used (see Table-1). Similar procedure is adopted by James et. al. for RHA preparation [16]. The time of burning affects the RHA obtained i.e., lower amounts of RHA are produced when heated for 5 hours as compared to a time of 3 hours. This shows that heating for longer time helps to burn out more organic matter i.e., carbonaceous mass is lost [17] with SiO 2 undergoing structural changes i.e., amorphous silica formation. Free corrosion potential measurements are widely accepted for the identification of passive and active areas of rebar embedded in concrete. ASTM specification 876-87 (1987) states that the potential values more noble than -0.20 CSE signify a 90% probability that steel is passive in this area. Potentials below -0.35 V CSE indicate that a 90% probability exists for corrosion. The values between -0.20 V to -0.35 V CSE show that corrosion of steel in this area is uncertain. The free corrosion experiments conducted on the st eel specimens embedded in various mixed mortars, showed very interesting features. The Ecorr of a clean mix with cement/sand ratio of 1:3, show that the specimen is passive, see Figure-1. Fig. 1. Comparison of mortars with different OPC: sand ratios and no RHA In comparison to 1:3 mortars, the 1:1 cement/sand ratio shows lower potential values. This shows that the specimen in 1:3 mix is having plentiful supply of O 2 to support passivity of steel. The potential slowly moves down after 17 days of hydration as the pores close and the oxygen at the surface of steel starts to diminish. As the OPC is hydrating in 1:1 mortar, the porosity is decreasing. Higher OPC content and, therefore, more hydration of cementitious compounds and hence, more compaction till 7-days limited the O2 access to the embedded steel forcing towards a limiting cathodic reaction. Plausibly a crev ice developed that forced the potential to drop down. No pits were observed on visual inspection of the specimen. After 17-days when hydration reactions are stabilizing, the steel starts to passivate. May be the crevice healed and the potential did not fall further. 71 Fig. 2 shows the effect of different percentages of RHA by weight of OPC containing 1% NaCl. The results show that an increase in the percentage of RHA i.e. 10-20% by weight of OPC increases the Ecorr values, improving the condition of steel by pushing the Ecorr in the passive direction. The specimen containing 10% replacement of OPC by RHA showed pitting as potential kept on drifting down to Ecorr of -693 mV. Increasing RHA to 20% by weight of OPC improved the Ecorr values to a region of -330 mV. This specimen did not show any pit on visual inspection. RHA (20% by weight of OPC) aids in cement hydration i.e., more C-S-H formation and hence more release of Ca(OH) 2 in the pore solution. Accelerated hydration by RHA is supported by other researchers[14, 18]. Hausman[3] has stated that a critical Cl -/OH- ratio must be maintained to ensure passivity of steel in concrete. Fig. 2. Comparison of mortars with different OPC: sand: RHA ratios Increasing the RHA further to 30% also shows the same i.e., more noble potentials than the sample with 10% RHA. However, it keeps declining very slowly. It seems that some corrosion activity is present but at a very slow rate. The results of set 3 which shows the effect of increasing the sand content for the best sample i.e., 20% RHA mortar with 1 % NaCl are presented in Fig. 3. Increasing the sand in OPC mortars result in poor protection properties of steel in concrete. Higher OPC / sand ratios do not protect the steel at all. Though RHA replacement is done the Ecorr continued to shift down showing pit activity. The studies show clearly that an increase in RHA does retards corrosion but OPC must be maintained at a certain level to mitigate corrosion in presence of NaCl. The same may be deduced by comparison of 1:3 OPC: sand mortar of Fig. 3 with Fig. 1. The RHA addition is of no help in presence of NaCl i.e., certain amount of OPC must be present to provide adequate amount of OH- ions. 72 Fig. 3. Comparison of mortars with different OPC: sand ratios Here RHA addition does not improve the condition for the NaCl is taken as an admixture when sand content is high. Hence, a high cement content is required for maintaining passivity of steel when NaCl is present as an admixture[19]. It is expected that RHA will be beneficial when chloride is present in the outside environment and has to diffuse to the steel surface to promote corrosion. The present studies show that the use of RHA as a valuable replacement material for OPC that not only increases the strength and lowers the porosity but can also retard corrosion when taken in a selected RHA/OPC/sand blend. Previous studies by G.C. Isaia (1999) have fo cused on the chloride ions from the outside of concrete, in which case RHA additions were found beneficial [20]. Our findings are based upon preliminary results during the hydration period with NaCl as an admixture. The next phase of studies will take the Cl- penetration from the outside environment in OPC mortars with RHA additions to ensure the role of RHA additions on corrosion of steel in outside contaminated environments. ACKNOWLEDGEMENTS The authors are indebted to thank Mr. Munir A. Rana, DGM of Cement Research and Development Institute (CRDI), TUSDEC, Kotlakhpat, Lahore, for giving a standard sample of OPC and Black Gold industry, Bund Road link, Bogiwal Road, Lahore for kind provision of the steel samples and. Our humble thanks are also offered to Prof. Dr. P.H. Armacost, the Rector, Forman Christian College – A Chartered University Lahore for provision of necessary laboratories facilities. REFERENCES 1. Akolzin, A. P., Ghosh, P., Kharitonov, Y. Y., 1985, Brit. Cor. J., 20, No. 1, p. 32. 2. Schwenk, W., 1985, “Betonwerk Fertigteil-Technik”, 51, No. 4, p. 216. 3. Hausman, D. A., 1967, “Mat. Protection”, 6, p. 19. 4. Chabannet, M. Pateha, K.P., 1992, Proc. Int. Conf. Cement Microsc., France., p. 157. 73 5. Rehm, G., 1984, “Betonwerk Fertigteil-Technik”, 10, p. 697. 6. Benjamin, S.E., Khalid, F.A. and Khan R. A., 2003, “Performance of Steel in Ordinary Portland, Fly Ash and Slag Cement during the Hydration Period”, J. of Materials Processing Technology, Vol. 103, Issue 3, pp. 383. 7. Farooq, M. K., 1980, Proc. Nat. Symp. Ener. Conser., Islamabad, Pakistan, p. 144. 8. Kamau, G.N., Mbinyo, J.K.N., Githinji, Z.P., Tuts, R.J.R., Kinyua, A.M., 1993, J. of biochemiphysics, 2, p. 138. 9. Yu, Q., Zhao, S., Feng, Q. and Sugita, S., 2003, 25(1), chap. 33, p. 15. 10. Folliard, K. J., Otha Makoto, Rathje, E., Collins, P., 1994, Cem. & Conc. Res., 24, p. 424. 11. Wada, I., Kawano, T., Kawakami, M., 1999, Semento, Konkurito Rohbunshu, 53, p. 347 (Japan). 12. Khane, A.R., 1988, Brit. Corr. J., 23, No. 3, p. 74. 13. Benjamin, S. E., 1990, Thesis, Oxford Univ., U.K., p. 66. 14. Kumar A. (1993) Rice husk ash based cements, mineral admixture in cement and concrete, progress in cementand concrete, Ed. Ghosh, S. N. Sarker S. L. and Harsh, S. ABI Books Pvt. Ltd. CGCRI, Kolkata, India, 4:342-367. 15. I. Wada, T. Hidenobu and K. Mokoto, 2002, JCA Proceedings of Cement & Concrete, 56, p.163 (Japanese). 16. James, J. and Rao, M. S., 1986, “Cement Concrete Research”, 16 p. 297. 17. Anwar, M., Miygawa, T. and Gaweesh, M., 2000, Construction Research Institute, NWRC, Delta-Barrage, Egypt 13621, Waste Manage. Ser., 1, Pergamon Press, pp. 671- 684. 18. Hwang, C. L., 1989, Am. Concrete – Inst., Fly Ash, silica fume, slag, nat. pozzolan concrete, 1, 114. 19. Benjamin, S. E. and Sykes, J. M., 1990, “Corrosion of Reinforcement in Concrete Construction”, Eds. Page, C. L., Treadaway, K. W. J. & Bamforth, P. B., SCI : Elsevier Sc. Publishers, London, p. 59. 20. Isaia, G.C., 1999, Mod. Conc. Mater. Proc., Brazil, 195.
Filename:
11-Corrosion-of-Mild-Steel-in-Opc-Rha-Mortars-By-S.-E.-Benjamin-and-Wajjid-Ali-Shah.pdf
File Type:
pdf
File Size:
107 KB
Categories:
Volume 0044 No 01
Downloads:
2
