88 TO STUDY THE CORROSION TENDENCY OF API X-70 IN BASE OIL ENVIRONMENTS By M. Z. Khalid*1, F. Hussain1, M. T. Z. Butt1 and M. A. Butt2 Abstract In this research work the corrosion tendency of different surfaces of API X-70 petroleum pipeline steel in Base oil emulsion and Base oil extract has been evaluated by Potentiodynamic Tafel scan. The results demonstrated that formation of an oily film on the surface of material decrease anodic dissolution of steel that ultimately increase polarization resistance. Corrosion rate in base oil extract was higher than oil/water emulsion due to the absence of oily film at ground and polished surfaces by promoting of oxygen reduction reactions at a limiting current density in Base oil extract which controlled corrosion ph enomenon at ground surface with minor influence on polished steel surface. It was also revealed that the polished surface of X-70 has lower value of I corr compared to rough surface in both Base oil extract and emulsion. Hence accelerated degradation of rough surface compared to polished surface in base oil will occur. Key Words: – Corrosion; Potentiodynamic; Steel; Base oil; Polarization; 1. Introduction Base oil is a lubrication grade oil that is produced initially from refining crude oil (mineral base oil) of hydrocarbons containing paraffins, naphthenes,(no or very little olefins), aromatics, unsaturated hydrocarbons, sulfur compounds and large varieties of other compounds. There are two major types of base oil depending upon their molecular structure and viscosity index (VI), Paraffinic and Napthenic .Paraffinic base oils have linear chain structure and viscosity index >95 whereas Napthenic base oils have branched chain structure and viscosity index 0 -40. Paraffinic base oils are preferable as compare d to Napthenic in lubrications due to its better Physico – chemical properties [1 – 2]. It is a matter of fact that the most reliable and effective way to transport oil and gas is to utilize a pipeline system. However, due to the effect of long term wear ou t and prevailing surrounding environments, the pipeline always be deformed and corroded. This may happen because along with the oil some amount of water and complex compounds such as carbonates, sulphides, etc also flow through the pipeline that may cause degradation and erosion of pipeline material. In other words we may say that erosion -corrosion of pipeline has occurred. During the transportation of Base oil within the refinery through pipeline some amount of water is also carried along with it. The compo unds present in base oil and water ends up with the start of pipeline corrosion. This degradation of the pipeline material results in the leakage of pipe. Corrosion of pipewalls can either be internal or external. In this research work the internal corrosion of pipe line material has studied .It may occur due to the presence of carbon dioxide, hydrogen sulphide, microorganisms especially bacteria, high flow speed, deposition of solid particles, water hold up etc. Many research studies have already been c arried out on Oil/Gas pipeline corrosion. The principal objective of these studies was how to protect the valuable pipeline material and minimize losses which mainly occur due to the corrosion [3 – 4]. Carbon steels and High Strength Low Alloy (HSLA) steels are particularly susceptible to intense corrosion in CO2 / H2S environments [5]. The experimental study undertaken in this research work is “To study the corrosion tendency of API X-70 in Base Oil Environment”. The focus of the work was to investigate the corrosion _____________________________________________________________________________________________ 1. Department of Metallurgy & Materials Engineering, CEET, University of the Punjab, Lahore, 54590, Pakistan. 89 2. Institute of Chemical Engineering & Technology, University of the Punjab, Lahore, 54590, Pakistan. tendency of oil / gas pipeline material to corrode in Base oil environments such as extract and emulsion. Rate of corrosion may also be affected by changing the transportation ra te of O2 and reactants from the surface of material [6]. Other factors like time, temperature and pressure are also responsible of higher corrosion rate. 2. Experimental Work 2.1 Chemical Composition The subject material in this research work is an in -service pipeline steel specimen of API X -70, under API 5L standard, regarding X -70 steel pipes as large diameters steel pipe. It mainly consists of Mn (1.234), P (0.015), Cr (0.027), Si (0.281), V (0.035) and small percentage of Ti, Ni and remaining amount of Fe. 2.2 Surface Preparation The metallographic examination of API grade x -70 were carried out by cutting the specimens into 1 x 1 cm 2 dimensions and then cold mount ed. Each specimen of X-70 was first ground by using emery papers of grit sizes 120, 220, 320, 400, 600 and 1000 respectively and then polished on billiard cloth by utilizing aluminum oxide as an abrasive to produce scratch -free and mirror-like surface. Two types of surfaces were prepared for electrochemical testing. One type of surface was prepared by grinding the specimen up to 600 grit silicon carbide paper and the second type was prepared by grinding up to 1000 grit silicon carbide paper and polish ed to a mi rror finish using one micrometer Alumina power. The SEM results of ground and polished surfaces are shown in figures 1 – 2. Figure 1: SEM result of rough surface of API X-70 Figure 2: SEM result of polished surface of API X-70 90 2.3 Base Oil Characterization The physico -chemical properties of Base oil, such as Kinematic viscosi ty (ASTM D 7042 -04) [7], Density (ASTM 5002 -99), and specific gravity (bottom flask method) were determined by standard ASTM methods. The viscosity and density were measured by pouring a sample in to the dig ital Automa tic Analyzer Stabinger SVM 3000 Anton Paar. The subsequent analysis of bas e oil extract by Potentiometric titration measured NaCl (ASTM D 6470) that is described in (w/w) Percentage [8]. Amount of Sulphur content was measured according to Standa rd Test method for sulphur in petroleum and petroleum products by X -ray fluorescence spectrometry (Standard D 4294-08)[9]. The base oil characterization has shown in Table-1. Table 1: Base Oil Characterization Physical Properties Result Density 0.841g/cm3 Specific Gravity 0.812 Viscosity index 97 Kinematic Viscosity 0.0372 Strokes 2.4 Testing Environments The test solutions were oil / water emulsion and crude oil extract. For the preparation of oil/water emulsion, a sample of base oil from Nationa l Oil Refinery Ltd, Pakistan was collected and used for the studies performed in this paper. The standard practice was followed for all of the procedure using one aliquot of the collected crude oil. The ratio of oil to water phases in oil / water emulsion was (15: 85). One fraction of the same bas e oil, with BSW equal to 15% V/ V, was used to prepare emulsion by adding free water. The oil and water were emulsified in the presence of a surfactant (DSS) 1% (w/v) manually then continuous stirring was carried o ut so that a stable oil/water emulsion can be obtained. The sample rested for 24h to confirm the stability of the emulsion. The bas e oil extract was prepared b y mixing of tap water with base oil having ratio 3:1 in a separating funnel. The intermittent mi xing of immiscible water -oil mixture for three hours was carried out and allowed to separate for 24 hours at room temperature. Thus, bas e oil extract was obtained and its chemical analysis is carried out in L aboratory that s hows the increased amount of sp ecies like Cl, Ca, Mg, pH etc as compared to tap water. The elemental Analysis was also carried out according to standard ASTM methods that show the presence of sulphur, residue carbon and ash content in weight percent. 2.5 Electrochemical Testing The elec trochemical testing was carried out in a three electrode cell. It consists of saturated calomel electrode as reference electrode and graphite rod as counter electrode, whereas the X – 70 steel sample acted as a working electrode. Epoxy embedded electrode were made to use as a working electrode. In this electrode electrical connection was made with soldering. A glass tube was used to accommodate the conducting wire. When metal specimen holding with glass tube was positioned, pour the epoxy on to the specimen. Epoxy was used with hardener and both of them were properly mixed before po uring. Approximately give 1 – 2 hour for hardening. After the proper hardening of epoxy, grinding and polishing processes were done by following the standard metallurgical procedures. While grinding and polishing made an attempt to prepare flat and smooth surface for accurate corrosion studies. Prior to electrochemical measurements, the electrode was immersed in the test solution for 30 minutes until steady state corrosion potential was achieved. The values of potential and current versus time were measured until a stationary state condition was obtained. The experiments were conducted at 250C. 3. Results and Discussion 91 Potentiodynamic Tafel scan is a direct electrochemical measuremen t utilized for evaluating the corrosion performance. In this technique, corrosion current density and potential are extrapolated from the polarization profiles scanned across the cathodic and anodic regimes. Cell current is measured during a slow sweep of the potential. The sweep is from -250 to +250 mV relative to Eoc. With respect to the selected polarization ranges and potential scan rates, the characteristic performance of the tested API X -70 steel pipeline material is revealed in a typical environmental condition as an electrochemical fingerprint. Potentiodynamic Tafel scan can give a better understanding on the possible multi -step anodic dissolutions, from the variations in the potential / current slopes in the prepassivation ranges. Furthermore, it indicates the importance of the environmental conditions on the passivation from the potential ranges, anodic peaks and from the associated accelerated and/or decelerated current densities. Complex ions present in base oil, dissolves in the multiphase pipel ine flows at different extents, depending on temperature and pressure, producing the corrosive carbon carrying species. These species, besides the conventional salinity, also contain the weak carbonic acid (H 2CO3), bicarbonate (HCO 3 -), and carbonate ( CO 3 -2) which drive the corrosion reactions in different fashions depending on their concentrations and on pH levels [Kermani, 2003]. From the variations of the corrosion potentials along with the decelerated corrosion current densities, it was found that oil can act as an anodic or a cathodic inhibitor with respect to temperature, and from the sudden acceleration in the anodic current densities at high overpotentials, important hints on the oil adsorption were revealed accordingly. The graphical representation of Tafel scan curves for ground specimen of API X-70 both in base oil extract and emulsion, as well as of polished specimen in base oil extract and emulsion are shown in figure 3 – 6. The results obtained from Tafel scan curve have shown in T able 2 – 3. It is inferred from these results that the corrosion rate of ground surface of X-70 steel is higher than the smooth surface. The reason is that the ground surface have more exposed surface are a as compared to polished one .T he oxidation tendency of groun d surface is also more as compared to polished one .It has also apprehended from res ults that corrosion rate in bas e oil extract is also greater than base oil emulsion. The reason for this behavior is that base oil extract is more corrosive for API grade X -70 steel, due to the high concentration of chloride ion, carbonates present in extract and high oxidation potential of oxygen. Figure 3 : Tafel Scan of API-X-70 (Ground Surface) in Base Oil Extract 92 Figure 4: Tafel Scan of API-X-70 (Polished Surface) in Base Oil Extract Figure 5: Tafel Scan of API-X-70 (Ground Surface) in Base Oil/Water Emulsion Figure 6: Tafel Scan of API-X70 (Polished Surface) in Base Oil/Water Emulsion 93 Table 2: Tafel Parameters of API-X-70 in Base Oil Extract Sample ID Surface Condition Electrolyte Tafel Parameters βa (V/decade) βc (V/decade) Icorr (A/cm2) Ecorr (mV) Corrosion Rate (mpy) X70-GBE-T Ground Base Oil Extract 75.00E-3 262.3E-3 12.10E-6 -772 5.549 X70-PBE-T Polished 103.1E-3 578.6E-3 10.50E-6 -701 4.805 Table 3: Tafel Parameters of API-X-70 in Base Oil/Water Emulsion Sample ID Surface Condition Electrolyte Tafel Parameters βa (V/decade) βc (V/decade) Icorr (A/cm2) Ecorr (mV) Corrosion Rate (mpy) X70-GBEM-T Ground Base Oil/Water Emulsion 274.3E-3 387.2E-3 7.370E-6 -607 3.374 X70-PBEM-T Polished 365.1E-3 464.9E-3 5.880E-6 -443 2.693 4. Conclusions It is inferred f rom Potentiodynamic Tafel Scan results that the corrosion rate of ground surface of X-70 steel is higher than the smooth surface. The reason is that the ground surface has more exposed surface area as compared to polished one. The oxidation tendency of ground surface is also more as compared to polished one.The Tafel parameters i.e βa, βc, I corr and Ecorr also in support of these results. 5. References [1] Base Oils I -The Basic of Refining David Lindsay & Paul Vettel. [2] Base Oils II-What Makes a Good Lubricant? David Lindsay & Paul Vettel. [3] External Corrosion of Oil and Natural gas pipelines”.John A.Beavers and Neil G.Thompson,ASM HandBook,Vol13c,corrosion environment and industries. [4] Parametric study of CO 2/H2S Corrosion of carbon Steel used for pipeline applications.G.S.DAS&A.S.KHANNA Corrosion Science. [5] Corrosion of Oil-Field Pipelines V.VZAV:YALOVNizhnevartovsk Research and Development Institute of Oil industry,UL.lenina 5a,Nizhnevartovsk,628616 Russia. [6]The corrosion of Carbon Steel in Oil/Water emulsion under controlled hydrodynamic conditions.Haydee Quiroga Becerray,C.R Etamoso,DIgby D.Macdonald [7] ASTM D7042 -04.Standard test method for dynamic viscosity and density of liquids by Stabingerviscometer(and calculation of kinematic viscosity). 94 [8] ASTM D6470-99,Standard test method for salt in crude oils(potentiometric method).. [9] ASTM D4007-08.Standard test method for water and sediment in crude oil by centrifuge method. [10] X. Tang, L.Y. Xu, Y.F. Cheng, Electrochemical corrosion behavior of X -65 steel in The simulated oil sand slurry II: Synergism of erosion and corrosion, Corrosion Science 50 (2008) 1469. [11] B.R. Tian, Y.F. Cheng, Erosion -corrosion of hydrotransport pipes in oil sand Slurries, Bulletin of Electrochemistry 22 (2006) 329. [12] Y. Li, G.T. Burstein, I.M. Hutchings, The influence of c orrosion on the erosion of Aluminium by aqueous silica slurries, Wear 186–187 (1995) 515. [13] Y. Li, G.T. Burstein, I.M. Hutchings, Influence of environmental composition And electrochemical potential on the slurry erosion –corrosion of aluminium, Wear 18 1–183 (1995) 70. [14] G.T. Burstein, K. Sasaki, Effect of impact angle on the slurry erosion –corrosion Of 304L stainless steel, Wear 240 (2000) 80. [15] E.A.M. Hussain, M.J. Robinson, Erosion–corrosion of 2205 duplex stainless steel In flowing seawater containing sand particles, Corrosion Science 49 (2007) 1737. [16] M.M. Stack, S. Lekatos, F.H. Stott, Erosion –corrosion regimes: number, Nomenclature and justification?, Tribology International 28 (1995) 445 [17] M.M. Stack, T.M. Abd-El Badia, Mapping erosion–corrosion of WC/Co–Cr based Composite coatings: Particle velocity and applied potential effects, Surface and Coatings Technology 201 (2006) 1335. [18] A. Neville, M. Reyes, T. Hodgkiess, A. Gledhill, Mechanisms of wear on a Cobase Alloy in liquid–solid slurries, Wear 238 (2000) 138. [19] H.X. Guo, B.T. Lu, J.L. Luo, Interaction of mechanical and electrochemical factors In erosion–corrosion of carbon steel, Electrochimica Acta 51 (2005) 315. [20] H.Q. Becerra, C. Retamoso, D.D. Macdonald, The corrosi on of carbon steel in oilin -Water emulsions under controlled hydrodynamic conditions, Corrosion Science 42 (2000) 561. [21] R.A. Mac Kay, N.S. Dixit, Micro -emulsions as photogalvanic cell -fluids-the Surfactant thionine iron(II) system, Journal of Physical Chemistry 86 (1982) 4593. [22] P. Becher (Ed.), Encyclopedia of Emulsion Technology, Applications, Marcel Dekker Inc., New York and Basel, 1985. [23] H. Bouazaze, F. Huet, R.P. Nogueira, A new approach for monitoring corrosion And flow characteristics in oil/brine mixtures, Electrochimica Acta 50 (2005) 2081. [24] F. Huet, R.P. Nogueira, Comparative analysis of potential, current, and Electrolyte resistance fluctuations in two-phase oil/water mixtures, Corrosion 59 (2003) 748. [25] B.R. Tian, Y.F. Cheng, Electrochemical corrosion behavior of X-65 steel in the Simulated oil sand slurry. I: Effects of hydrodynamic condition, Corrosion Science 50 (2008) 773. 95 [26] A.J. Bard, L.R. Faulkner, Electrochemical Methods: Fundamentals and Applications, second ed., John Wiley & Sons, New York, 2001. [27] A. J. Bard, L. R. Faulkner, Electrochemical Methods: Fundamentals and Applications, second ed., John Wiley & Sons, New York, 2001. [28] V.G. Levich, Physicochemical Hydrodynamics, Prentice-Hall, Englewood Cliffs, NJ, 1962. [29] A Manual Of Corrosion Testing And Monitoring Using Advanced Electrochemical Techniques, Corrosion Control Research Cell Faculty Of Engineering And Technology, University Of The Punjab Lahore, Pakistan. [30] National Energy Board, Canada’s Oil Sands: A Supply and Market Outlook to2015, October 2000, p. 23.s [31] S. Das, Y. L. Saraswathi, D. P. Mondal, Erosive –corrosive wear of aluminum alloy Composites : Influence of slurry composition and speed, Wear 261 (20 06) 180.[5] A. Neville, F. Reza, S. Chiovelli, T. Revega, Erosion –corrosion behaviour of wcbased Mmcs in liquid–solid slurries, Wear 259 (2005) 181 [32] V.A.D. Souza, A. Neville, Aspects of microstructure on the synergy and overall Material loss of thermal spray coatings in erosion–corrosion environments, Wear 263 (2007) 339.

Filename: 88-95To-study-of-corrison.docfinal.pdf
File Type: pdf
File Size: 386 KB
Categories: Volume 0044 No 03-04
Author: F. Hussain1, M. T. Z. Butt and M. A. Butt, M. Z. Khalid