57 GROUND WATER INVESTIGATIONS USING ELECTRICAL RESISTIVITY SURVEY IN RECHNA DOAB, PUNJAB, PAKISTAN By Ghulam Zakir Hassan1, Faiz Raza Hassan2 and Saleem Akhtar2 ABSTRACT Ground water quality is deteriorating in certain areas of the Punjab owing to excessive pumping by tubewells and many other factors. Electrical Resistivity Survey (ERS) is a technique which is applied to investigate the potential of fresh ground water in an aquifer . Electrical Resistivity Survey was carried out at nine locations upto a depth of 250-300 m on the left side of Jhang Branch Canal (JBC) in the vicinity of Faisalabad city in Punjab Province of Pakistan . The equipment used for ERS was ABEM, Terrameter SAS 1000 IP, SP, and Resistivity System. The resistivity data collected has been interpreted by computer -aided techniques using computer software. The Quality of ground water from 10 to 60 meter depth is marginal to saline which improves afterwards gradually upto the depth of 150 m and afterwards deteriorates at locations R-1 and R -2. At site R -3 it contains top surface material upto 12 m and afterwards there is marginal to saline water. At sites R-4, R-6, and R-9 resistivity value is in the category of Low Resistivity Zone only a small layer contain s fresh quality water and the rem aining three sites also fall in Low Resistivity Zone. Key Words: Resistivity, Ground water ; Aquifer, Quality; ERS; Rechna Doab, Punjab, Faisalabad, Pakistan. 1. Introduction Faisalabad is the third largest city of Pa kistan with a population of 6.047 M and is the hub of industrial activities in the country. Ground water underlying the city is brackish and water is transported by means of underground piping network from the nearby aquifer near the Chenab River on Western side of the city mainly for drinkin g purposes. Already a well field is working since 1992 at a discharge capacity of 1 , 55,351 m3 / day on the Western side of Jhang Branch Canal (JBC) near the village Rajoa. Recently a new well field with an anticipated pumping capacity of 1 80,000 m3 / day with funding from JICA along left bank of JB C is almost near commissioning. In addition to these pumping s, the area surrounding the city is agricultural area and private farmers tubewells are also pumping ground water to meet with the crop water requirements. Faisalabad Development Authority (FDA) has launched a housing scheme name ly “FDA City Housing Scheme” to meet the housing demand for ever increasing population of Faisalabad. The housing scheme is located on Faisalabad -Sargodha road near motorway (M3) interchange at Faisalabad spreading over an area of 1,256 acres. FDA is interested to install tubewells along the Jhang Branch Canal near RD 209-216 of proposed capacity of 20,000 m3 / day to meet the water requirements of this new housing scheme. Keeping in view the socio -environmental impacts of the existing well field it was deemed imperative to get the seepage and ground water investigations carried out before installation of the proposed well field. Accordingly, Irrigation Research Institute (IRI) of Punjab Irrigation Department was assigned the job. Main objective of the study was to assess the possibility of development of environment friendly well field and safe abstraction of ground water for water supply to FDA -City housing scheme. Current study on performance of Electrical Resistivity Survey (ERS) in the field has been accomplished as a part of the main study on ground water investigations. Some uses of ERS method in ground water are: determination of depth, thickness and boundary _____________________________________________________________________________________________ 1. Director, Irrigation Research Institute (IRI), Government of the Punjab, Irrigation Department, Library Road Lahore, 54000, Pakistan. Corresponding author’s e-mail: zakirjg@gmail.com 2. Assistant Director, Irrigation Research Institute (IRI), Government of the Punjab, Irrigation Department, Library Road Lahore, 54000, Pakistan. Corresponding author’s e-mail: faizrazahassan@gmail.com 58 of an aquifer, determination of interface of saline water and fresh water, porosity of aquifer, hydraulic conductivity of aquifer, specific yield of aquifer and contamination of ground water CHOUDHURY, et al (200 1). In recent years many investigations have revealed that in certain areas of the Punjab, the drinking water quality is significantly deteriorated with respect to certain constituents such as faecal coliforms, pesticides, nitrates, fluorides and chromium by PROF. DR. JAVAD. A. AZIZ. 2. Study Area Study area fall s in the Rechna Doab (the land between river Ravi and Chenab). The Rachna Doab, as a whole, is an inter -fluvial area and lies between longitudes 71. 48’ E to 75. 20’ E and latitude 30 to 32. 51’. Rachna Doab covers a gross area of about 2.97 million hectares which is mainly under irrigated agriculture and falls in the rice -wheat and wheat -sugarcane agro – ecological zones of the Punjab Province. It covers a vast canal network up to distributaries and minors. The Rechna irrigation system consists of Lower Chenab Canal (LCC), Upper Chenab Canal (UCC), Bomban–wala Ravi Badian Depalpur (BRBD) Canal, Marala -Ravi (MR) Link and Trimu-Sidhnai (TS) Link canal. Agriculture is the major economic activity with Kharif and Rabi as two crop seasons . The kharif season extends from April to October which covers monsoon season; Cotton, Rice, Sugarcane and Maize are grown durin g this season of the year where as Rabi which is dry and prevail s from September to March; wheat is m ain crop of this season ZAMIR-UDDIN KIDWAI, (1962) . Climate of Rechna Doab is characterized by large seasonal fluctuations of air temperature and rainfall. Climate of Rechna Doab is characterized by extremely hot in summers and mild in winters. The summers are long and hot, lasting from April through September, with maximum air temperature ranging from 21°C to 49°C. Winter lasts from December through February, with maximum air temperature ranging from 25°C to 27°C during the day and sometimes falling below zero at night. The spring and fall months are generally limited to March and October. The monsoon rain occurs from mid -July to mid – September caused by winds arising from the Bay of Bengal whereas the winter rains normally originate from the Arabian Sea. An nual precipitation is about 370 mm. The monsoon accounts for about 75% of annual rainfall. Location of study area is shown in Figure-1. 59 Figure-1: Location of Study Area in Rachna Doab 3. Literature Review The electrical resistivity of an alluvium is related largely to the water content, the ground water salinity and the clay content. Below the water table, the water content is controlled by the porosity and hence, by the lithology. In the case of sand and silts the porosity will depend on degree o f sorting and, to a lesser extent, the angularity of the grains and the degree of compaction. Clays show low resistivity values because of the ability of the clay minerals to attract ions and water. Emenike, (2001) tested the ground water potential and a c orrelation of the curves with the lithologic log from a nearby borehole and suggested that the major lithologic units penetrated by the sounding curves were laterite clay sandstone and clay . The sandstone unit, which was the aquiferous zone, had a resistiv ity range between 500 ohm-m and 960 ohm- m and thickness in excess of 200 m. The option of a particular method is governed by the nature of the terrain and cost considerations. Contamination frequently reduces the electrical resistivity of fresh water due t o increase of the ion concentration by FROHLICH, et al (2002) . Conversely, as resistivity methods are used, constraint can be expected if soil inhomogeneties and anisotropy are offered by MATIAS, (2002) . Electrical sounding method provides an inexpensive method for characterizing the ground water conditions of the region. ERS tests also revealed three sub -surface geo -electric layers consisting of surface layer (top soil), alluvium layer and saturated (bottom soil) layer by ARSHAD, et al (2007). ERS techniqu e, using resistivity meter, is effective to study ground water conditions and to assess the subsurface geo- electrical layers by OSEJI, et al (2006) . The geo-electrical method (ERS technique) has been used successfully for investigating the ground water potential and its quality in different lithological settings because the instrumentation is simple, field operations are easy and the analysis of data is economical and less tedious than other methods by EKINE, et al (1996). Low Resistivity Zone 0 -30 ohm-m, containing clay / silt or alternate layers of clay and sand saline water (expected EC above 1500 µ S / cm). Medium Resistivity Zone 31 – 100 ohm-m 60 containing alternate layers of clay and sand with fresh water (expected EC below 1500 µ S / cm). High Resistivity Zone above 100 ohm-m containing dry strata above water table by (WAPDA), (2008). Resistivity < 15 ohm -m, admixture of fine sand, clay and silt with brackish quality of water. Resistivity 15 - 25 ohm -m fine to medium sand intermixed thin silty clay containing marginal to saline water. Resistivity > 25 ohm -m medium to coarse sand or kankers intermixed thin silty clay layers containing fresh quality water by IRI, (2012). The aquifers having different ground water salinities were classified into fit, marginally fit and unfit for irrigation purpose. The ground water quality in aquifer having resistivity more than 45 m is safe for irrigation purpose, between 25 to 45 m is marginally fit and resistivity less than 25 m is unsafe for irrigation purpose. The interpreted subsurface hydrogeological conditions were classified into three resistivity zones by SIKANDAR, et al (2008). With the help of ERS technique fresh water layers could be targeted for drilling a well upto the lower end of these layers to avo id unnecessary drilling. The thicknesses of these layers also guide us for well site selection at a point, which has bigger thickness within the land holding of the farmers. This technique is a non -destructive and useful method to detect depth and thickness of various subsurface geological formations and the ground water quality within these formations of the layers by SIKANDAR, et al ( 2010). The transmissivity T values calculated from the Vertical Electrical Survey ( VES) results range from 0.48 to 19.50 m2 / day while the equivalent obtained from pumping test vary from 1.07 to 33.74 m2 / day by OKORO, et al (2010). The use of electrical resistivity survey for assessing the ground water quality and aquifer potential has increased over recent decades in the w orld due to rapid advances in geophysical investigations by LASHKARIPOUR, et al (2005). 4. PERFORMANCE OF TESTS IN FIELD ERS were carried out in the field at nine locations to ascertain the geo-physical features of the aquifer. Besides, ERS, boreholes wer e drilled at some locations to verify the results of ERS. Similarly, ground water quality from existing tubewells in the study area was checked at the spot for comparison up to certain depth. Locations of these sites are shown in Figure -2 and ba sic features are given in Table-1. Table-1: Basic Features of ERS Test Sites Sr. No ERS Site No. Location Address Northing (m) Easting (m) Depth of Investigation (m) 1. R-1 Left Side of JBC at RD 212 3503788.9 318722.8 250 2. R-2 Left Side of JBC at RD 208+600 3504726.3 319271.3 250 3. R -3 Near Railway station Burj Mandi 3504272.5 319542.2 250 4. R -4 South East side (about 300 ft) of Chak No 20JB Khankay 3505659.8 323460.6 300 5. R -5 Chak No 23/JB Noon Bhattian, 3502793.5 321499.2 300 6. R -6 Chak No 109/JB, Nilian wala, 3497271.3 322770.8 300 7. R -7 Chak No 25/JB Sathio wala, 3499332.0 323014.8 300 8. R-8 Chak No 157/JB Gojra, 3503470.3 327827.5 300 9. R-9 Chak No 24/JB Lahorian wala, 3503402.6 324597.4 300 Electrical Resistivity method can easily be employed for subsu rface investigations where electrical resistivity contrast exists among the subsurface formations. Considering the variable electrical properties of subsoil , the technique of electrical resistivity survey make s use of measuring the cu rrent and potential differences of different subsoil material at the surface. Generally, current conduction is electrolytic in the soils and rocks containi ng interstitial fluids. The resistivity is controlled by porosity , water content , as well as the quantity of dissolved salts. Since clays are capable of storing electrical charges so their behavior is electronic and electrolytic. 61 Performing Electrical Resistivity Survey in Study Area at Different Site 62 Figure-2: Location of test sites in study area Thus the resistivity of soils and rocks depends upon the Resistivity of contained electrolyte and clay minerals and is inversely related to the porosity and degree of saturation of the formation . Therefore , Resistivity of soils and rocks vary considerably not only from formation to formation, but also within the same layer. In particular the Resistivity variations can be large in unconsolidated sediments. It has generally been observed that the Resistivity increases progressively from fine grained to coarse grained material in the order which i s clay, silty clay , clay silt , silt, sandy silt, silty sand , sand gravels and boulders IRI, (2012) . The Resistivity increases progressively from fine grained to coarse grained material in the order which is clay, silty clay , clayey silt , silt, sandy sil t , silty sand , sand gravels and boulders. During resistivity survey , commutated direct or very low frequency ( less than 1Hz ) current is introduced into the ground though two current electrodes A and B inserted in the ground surface as shown schematically in Figure-3. Figure-3: Schematic Schlumberger Electrode Configurations 63 Schlumberger Electrode Configuration was used during this study because it is less laborious and provides good resolution of ho rizontal layer and good depth sensitivity by WARD, S. H. (1990). The average potential gradient measured between M and N is a close approximation to the potential gradient at center of the array by Lashkaripour, (2003). The potential electrodes M and N are inserted in the ground between the current electrodes A and B. The four electrodes can be arranged in any of the several possible patterns and these patterns are called Electrode configurations. By measuring the current (I ) between the two current electrodes A – B and the associated potential differences ( V ) between the potential electrodes M – N , the resistivity ( R ) is computed by the following well known Ohm’s Law as under:- I V K R (1) Where, “K” is called the geometric factor of the electrode arrangement. In homogeneous ground this is th e tr ue ground resistivity, but in anisotropic and non -homogeneous ground, it represents a weighted average Resistivity of the formation through which the current passes. Since subsoil is normally heterogeneous and anisotro pic the resistivity value computed from equation ( 1) is called apparent resistivity and is denoted as (a) SUBBA RAO, N. (2002). Therefore, I V K a (2) Where: a = Apparent resistivity in ohm -meter K = Geometric factor for individual electrode arrangement V = Potential difference in milli volts I = Current passing through ground in mil li amperes The apparent resistivity values are obtained from various dept hs from surface by extending the current and potential electrodes from its centre in a straight line. The spacing between the electrodes is maintained according to the specific configuration used. Schlumberger electrode configuration is commonly used. In configuration, distance between the current electrodes is very large compared with the distance between the potential electrodes. Lateral inhomogenities are easily identified in this c onfiguration and it requires less electrode spacing at the surface to achieve the required depth of investigation as compared to other configurations Resistivity-measuring equipment was used for recording current and potential difference in the field. Schlumberger electrode configuration was used for the survey. In case of Schlumberger array, the distance of the current and potential electrodes from the center, which are referred as AB / 2 and MN / 2 respectively, characterizes the array. MN / 2 is always kept sufficiently small relative to AB / 2. The average potential gradient measured between M and N is a close approximation to the potential gradient at the center of the array. In case of Schlumberger electrode configuratio n, the apparent resistivity is computed as under:- I V x MN 2 MN – 2 AB x a 22 (3) 64 The resistivity field curves are obtained by plotting the apparent resistivity values against depths on a bi -log graph paper. After smoothing the plotted curves all the field data is registered to computer. The interpretation of sounding is done with the help of computer and direct interpretation software. The resistivity sounding data collected from the area is interpreted by computer -aided te chniques using computer software. The layer models are calculated by an iterative procedure. During each iteration, the model parameters are adjusted and the deviation of the corresponding curve from the measured curve is checked. The deviation is defined by the RMSE (root mean square error), which is displayed after each iteration. At the end of calculations, the model, which results in the smallest error, is plotted showing layer’s true resistivity and corresponding thickness. 5. RESULTS AND DISCUSSION 5.1 INTERPRETATION OF ERS DATA The measured resistivity when subjected to evaluation process yields different sub -surface geo-electrical layers. These geo -electrical layers need a correlation with the sub -surface hydrogeological conditions for interpreta tion. Transformation of geo -electrical layers into hydrogeological zonings are essentially based on the information obtained from test holes, tube wells and other data of previous investigations conducted in similar areas. The evaluated resistivity values of the sub -surface layers and the assumed formation factor in the area has been used to estimate electrical conductivity of the ground water contained in the subsurface aquifer zones. Interpretation of ERS field data Distance versus apparent resistivity using Computer Software are shown in Figure -4. After correlating all the available information, the interpreted sub -surface hydrogeological conditions at each sounding location are presented in the for m of columnar section in Figure -5. Table-2: Resistivity Values versus Lithology Sr. No Resistivity Zone Resistivity Value Ohm-meter Interpretation Lithology 1. Zone above water Table Haphazard Surface Materials 2. Medium Resistivity Zone 25 Medium to coarse sand or Kankers Intermixed thin Silty Clay layers 3. Low Resistivity Zone 15- 25 Fine to medium sand Intermixed with thin Silty layers 4. Very Low Resistivity Zone < 15 Admixture of fine sand, clay and silt Source: IRI, (2012) Interpretation of ERS field data Distance versus apparent resistivity using Computer Software at some locations is given below:- 65 Site R-4 (Reference figure-2) Site R-5 (Reference figure-2) Approximate Resistivity (Ohmm) Approximate Resistivity (Ohmm) 66 Site R-6 (Reference figure-2) Site R-7 (Reference figure-2) Approximate Resistivity (Ohmm) Approximate Resistivity (Ohmm) 67 Site R-8 (Reference figure-2) Site R-9 (Reference figure-2) Figure-4: Distance vs Apparent Resistivity Approximate Resistivity (Ohmm) Approximate Resistivity (Ohmm) 68 Resistivity values for different depths for all nine test locations are as under:- Table-3: Summary of True Resistivity Values ERS Site Depth (meter) True Resistivity Ohm-meter ERS Site Depth (meter) True Resistivity Ohm-meter R-1 0 – 10 21 R-6 0.00 – 0.70 23 10 – 60 23 0.70 – 16.2 20 60 – 150 49 16.2 – 61.8 68.5 150 – 250 25 61.8 – 300 10.8 R-2 0 – 10 21 R-7 0.00 – 0.60 6.9 10 – 60 23 0.60 – 20.2 14.3 60 - 150 49 20.2 – 48.9 28.9 150 – 250 25 48.9 – 300 8.7 R-3 0.00 – 12 18 R-8 0.00 – 0.90 12.7 12.00 – 250 25 0.90 – 11.2 13.5 11.2 – 27.5 25.9 27.5 – 300 7.3 R-4 0.00 – 0.70 55 R-9 0.00 – 1.5 14.2 0.70 – 12.2 12.9 1.5 – 14.1 16.8 12.3 – 33.5 3.6 14.1 – 68.6 27.6 33.5 – 96.6 28.1 68.6 – 300 9.6 96.6 – 300 2.5 R-5 0.00 – 3.90 9.6 3.90 – 18.7 33.9 18.7 – 51.1 5.7 51.1 – 84.6 22.9 84.6 – 300 2.1 At R -1 site the resistivity of top surface material is slightly less which gradually increase s with depth and at the depth of 60-150 m the value of resistivity is 49 ohm -meter containing fresh layer of water and same situation has been observed at sit e R-2. At location R-3 the value of resistivity at 12-150 m depth is 25 ohm -meter with marginal to saline water . At site R-4 the value of resistivity gradually decrease s from top surface upto depth of 33m and increases after that upto the depth of 96 m where the resistivity value is 28 ohm -meter containing fresh layer of water. At site R-5 the value of resistivity at the depth of 4-18 m where the res istivity value is 34 ohm -meter containing fresh layer of water and after that gradually decrease s. At location R -6 the value of resistivity gradually decrease s at top surface an d increases at the depth of 16-62 m where the resistivity value is 68 ohm -meter containing fresh layer of water. At site R-7 the value of resistivity gradually decrease s at top surface and increases at the depth of 20-48 m where the resistivity value is 28 ohm -meter containing fresh layer of water. At site R-8 the value of resistivity at the depth of 11-27 m where the resistivity value is 25 ohm-meters with marginal to saline water . At site R-9 the value of resistivity at the depth of 14-68 m where the resistivity value is 27 ohm -meter containing fresh layer of water . Overall the quality of ground water from 10 to 60 meter depth is marginal to saline which improves afterwards gradually upto the depth of 150 m and afterwards deteriorates at locations R -1 and R -2. At site R -3 it contains top surface material upto 12 m and afterwards there is marginal to saline water. At sites R-4, R-6, and R-9 resistivity value is in the category of Low Resisti vity Zone only a small layer contain fresh quality water and the remaining three sites also fall in Low Resistivity Zone. At ERS points R -5, R-6 and R-9 69 resistivity value is sufficient enough to fall in the category of Low Resistivity Zone otherwise at remaining three points ER value is13 – 15 Ohm -m which is below 15 but still these three segments fall in the low resistivity zone category because electrical noise due to saline regime of the area has suppressed the values at these points. Interpreted litholo gy for this zone is predominantly admixture of fine sand, clay and silt containing brackish quality of water. The thickness of Very Low Resistivity Zone increases from R-4 to R-8 and there is slight decrease at R-9. On the basis of T rue Resistivity which is obtained by the use of comput er software in Figure -4 and in Table-3 is used to drawn Columnar View of Subsurface Lithology as shown in Figure-5. The depth to water table in the study area is generally 3 -7 meters as measured from observation well . With the help of computer software ERS data also indicated that depth to water table in the project area is generally more than 3 meters. The results obtained from interpretation of ERS data using computer software at different sites have been compared with borelog lithology obtained to some extent. To have a comparative idea for comparison purpose by drilling the test wells upto about 20 m depth indicate good comparison as depicted in Fi gure-6. Similarly, results of ground water quality tested at dif ferent locations near ERS test points are given in Table-4. Figure-5: Sub-surface Lithology by Resistivity Surveys 70 Figure-6: Comparison of Borelog Analysis with ERS Results Table-4: Ground water Quality Measured in field near ERS Sites Sr. No Types of Bore Address ERS Site TDS (ppm) EC (us/cm) Status 1 Tubewell Dera Ch. Mustaq Near R-1 527 823 Marginal to saline water 2 Hand pump Dera Ch. Mustaq Near R-1 598 934 Marginal to saline water 3 Hand pump Burj Mandi Near R-3 577 734 Marginal to saline water 4 Hand Pump Dera Mestri Gulzar Ahmed, Chak No. 20 JB Khanki,FSD Near R-4 1180 1844 Brackish quality of water 5 Tubewell Dera Mestri Gulzar Ahmed, Chak No. 20 JB Khanki, FSD Near R-4 1070 1672 Brackish quality of water 6 Tubewell Dera Abid Chadhar, Chak No 23 JB, Noon Bhattian Near R-5 885 1383 Marginal to saline water 71 Sr. No Types of Bore Address ERS Site TDS (ppm) EC (us/cm) Status 7 Tubewell Ch.Kala Guajr, Chak No.109 JB, Nilainwala Near R-6 1160 1813 Brackish quality of water 8 Tubewell M.Azam Bhota, Chak No. 25 JB Sathowali, FSD Near R-7 810 1266 Marginal to saline water 9 Tubewell Saeed Ahmed, Chak No. 106 JB Khachian, Near R-7 1060 1656 Brackish quality of water 10 Hand pump Chak No. 25JB Sathowali, Brick Klin, Faislabad Near R-7 1123 1755 Brackish quality of water 11 Hand pump Chak No.157 RB Gojra, Faisalabad Near R-8 1750 2734 Brackish quality of water 12 Tubewell Chak No. 24 JB Lahorian, Near R-9 1340 2094 Brackish quality of water 13 Tubewell Dera M.Ismail, Chak No.21 Jb Ranika chah Near R-9 1210 1891 Brackish quality of water 14 Hand Pump Chak No. 24 JB Lahorianwala Near R-9 2250 3516 Brackish quality of water It indicates that ground water quality determined through ERS is almost similar as derived from ground water quality checked in field from hand pumps / tubewells by Ec / TDS meters. 6. Conclusions Following conclusions have been derived on the basis of different tests / investigations performed in the filed : a. ERS data indicated that depth to water table in the proje ct area is generally more than 3 meters. b. Subsurface lithology is dominantly sand with intervening clay beds within the explored depth of 300 m. c. The quality of water deteriorates with depth particularly away from the canal towards south-east. d. At site R-1 and R-2 (near canal bank), the underground strata from soil surface to 10 m depth consists of clay mixed with sand traces. The quality of ground water from 10 to 60 meter is marginal to saline which improves afterwards gradually upto the depth of 150 m. and becomes slightly inferior after 150 m Strata beyond 20 m is almost sand.. e. At site R-3, the underground strata from soil surface to 10 meter is almost dry consisting of top surface material. The overall quality of ground water from 10-250 m is marginal to saline. Strata beyond 10 m is sand with thin layers of silt and clay. f. At site R-4, ground water quality is almost brackish except a layer of fresh water at 40 - 100 m depth with medium coarse sand. This fact has been verified by testing the ground water quality of nearby tubewell and hand pump which indicated TDS values of more than 1000 ppm. g. At points R-5, R-6, R-7, R-8 and R-9 electrical resistivity value is sufficient enough to fall in the category of very low resistivity zone having almost brackish water below a depth of 30-50 m with sandy strata. _____________________________________________________________________________________________ ERS = Electrical Resistivity Survey TDS = Total Dissolved Solids ES = Electrical Conductivity 72 h. The results of ground water quality and sub -surface lithology obtained by ERS are almost in close comparison with the results obtained by drilling test holes and testing ground water quality at site. i. The possibility of installing tubewells for water supply can be explo red along the canal bank only. 7. ACKNOWLEDGEMENTS Provision of funds for this research by Faisalabad Development Authority (FDA) is duly acknowledged. Sincere thanks are also extended to field formations of Irrigation Department and FDA to provide necessary data and support for accomplishment of this assignment. 8. REFERENCES 1. ARSHAD MUHAMMAD, J.M. CHEEMA AND SHAFIQUE AHMED, 2007. Determination of Lithology and Ground water Quality Using Electrical Resistivity Survey. INTERNATIONAL JOURNAL OF AGRICULTURE and BIOLOGY1560–8530/2007/09– 1–143–146. 2. CHOUDHURY, K., D.K. SAHA AND P. CHAKRABORTY (2001) . Geophysical study for saline water intrusion in a coastal alluvial terrain. J. Appl. Geophysics, 46: 189–200. 3. EKINE, A. S. AND G. I. OSOBONYE (1996) . Subsurface geo-electric sounding for the determination of aquifer characteristics in parts of Bonny Local Government Area of Rivers State, Nig. J. Phys. 85. 4. EMENIKE, E.A. (2001) . Geophysical Exploration for Ground water in a Sedimentary Environment: A Case Study fro m Nanka over Nanka Formation in Anambra Basin, Southeastern Nigeria. Global J. Pure Appl. Sci., 7: 1 5. FROHLICH, R.K. AND D. URISH (2002) . The use of geoelectrics and test wells for the assessment of ground water quality of a coastal industrial site. J. Appl. Geophysics, 50: 261–78. 6. IRRIGATION RESEARCH INSTITUTE (IRI), (2012), “GROUND WATER INVESTIGATIONS FOR WATER SUPPLY TO FDA -CITY HOUSING SCHEME, FAISALABAD (GROUND WATER MODELLING APPROACH) , IRR -PHY/577, Lahore Pakistan 7. LASHKARIPOUR, G. R. (2003) . An in vestigation of ground water condition by geoelectrical resistivity method: A case study in Korin aquifer, Southeast Iran. J. Spatial Hydrology. 3:1-5. 8. LASHKARIPOUR, G. R. AND M. NAKHAEI (2005). Geoelectrical investigation for the assessment of ground water conditions: a case study. Annals of Geophysics. 48:937 - 944. 9. MATIAS, M.J.S. (2002). Squary array anisotropy measurements and resistivity sounding interpretation. J. Appl. Geophysics, 49: 185–94. 10. OKORO, E I; EGBOKA, B C E; ONWUEMESI, A G (2010). Evaluation of the aquifer characteristic of Nanka Sands using hydrogeological method in combination with Vertical Electrical Sounding (VES). J. Appl. Sci. Environ. Manage. June, 2010 Vol. 14 (2) 5 – 9. 11. OSEJI, J. O., M. B. ASOKHIA AND E. C. OKOLIE (2006). Determination of ground water potential in obiaruku and environs using surface geoelectric sounding. Springer Science+Business Media, Environmentalist. 26:301-308. 73 12. PROF. DR. JAVAD. A. AZIZ, Drink water Quality in Punjab. Paper no. 616, Pakistan Engineering Congress, Lahore, Punjab, Pakistan 13. SIKANDAR P., A. BAKHSH, M. ARSHAD AND T. RANA (2008) . The use of vertical electrical sounding resistivity method for the location of low salinity ground water for irrigation in Chaj and Rachna Doabs. Environ. Earth Sci. DOI 10. 1007/s12665-009- 0255-6. 14. SIKANDAR P., A. BAKHSH, T. ALI AND M. ARSHAD ( 2010). Vertical Electrical Sounding (Ves) Resistivity Survey Technique to Explore Low Salinity Ground water for Tubewell Installation in Chaj Doab. J. Agric. Res., 2010, 48(4). 15. SUBBA RAO, N. (2002). Ground water prospecting and management in an agro -based rural environment of crystalline terrain of India. Environmental Geology. 43: 419-431. 16. WATER AND POWER DEVELOPMENT AUTHORITY ( WAPDA), (2008), Electrical Resistivity Studies for Ground water Investigations along Rakh Branch Canal Faisalabad, Hydrogeology Directorate, G.W.I. Note No. 453 17. WARD, S. H. (1990). Resistivity and induced polarization methods. Geotechnical and Environmental Geophysics, Vol. 1. Society of Exploration Geophysics. 18. ZAMIR-UDDIN KIDWAI, (1962), The Geology of Rachna and Chaj Doabs “Water and Soil Investigation Division Bulletin 5” West Pakistan, Water and Power Development Authority, Lahore, Pakistan.
Filename:
57-79-Groundwater-Investigations-Ghulam-Zakir-Hassan-Final-Shamara-no-9.pdf
File Type:
pdf
File Size:
688 KB
Categories:
Volume 0045 No 01-02
Downloads:
13
