Paper No. 702 DRINKING WATER QUALITY MONITORING WITHIN A DISTRIBUTION NETWORK: F-8 AND E-7 SECTORS OF ISLAMABAD Sara Qaiser, Syeda Asma, M. Talal Ali Khan, Imran Hashmi 600 Qaiser, Asma, Khan, Hashmi Pakistan Engineering Congress, 71st Annual Session Proceedings 601 DRINKING WATER QUALITY MONITORING WITHIN A DISTRIBUTION NETWORK: F-8 AND E-7 SECTORS OF ISLAMABAD Sara Qaiser, Syeda Asma, M. Talal Ali Khan and *Imran Hashmi Institute of Environmental Science and Engineering, School of Civil and Environmental Engineering, National University of Sciences and Technology, H-12, Islamabad, Pakistan *Correspondence: Ph; 92-(051)90854303 E-mail: hashmi71@gmail.com Abstract Most pollution of drinking water is caused by inadequacy of distribution system, by inefficient upkeep of the sewage system and by defects in the disinfection processes. This may be the cause of water borne epidemic outbreaks. Concern over the presence of faecal coliform in public drinking water supplies has been expressed in recent years in Pakistan, since it has been rega rded as a pathogenic organism, of prime importance in gastroenteritis. It is, therefore, necessary to carry out routine monitoring of the distribution system. The aim of this study was to monitor the quality of water in drinking water supplies at the treat ment plant and in the water distribution network of two major sectors, F -8 and E-7, of Islamabad, Pakistan. The drinking water distribution systems were monitored, over the period of one month, to assess the microbial water quality and residual chlorine. T he drinking water quality monitoring was performed by collecting samples from the water source and residential taps from each distribution network. The samples were analyzed for physico-chemical indicators (temperature, pH, conductivity, total dissolved so lids (TDS), turbidity, total chlorine, free chlorine residual and chloramines) and bacterial indicators (total and faecal coliforms). In the sector F -8, temperature ranged from 19.6°C to 22.6°C, TDS varied between 156.0 mg/L and 268.0 mg/L, turbidity ranged from 2.70 to 8.15 NTU, pH varied from 6.96 to 7.48, conductivity ranged between 325 and 548 S/cm, total chlorine observed varied between 0.14 mg/L and 0.21 mg/L, total coliforms ranged from undetectable level to 2.2 most probable number (MPN)/ 100 mL. I n sector E-7, temperature ranged from 20.4°C to 21.7°C, TDS varied between 157.4 mg/L and 163.2 mg/L, turbidity ranged from 1.30 to 4.46 NTU, pH varied from 7.26 to 7.65, conductivity ranged between 328 and 339 S/cm, total chlorine observed varied between 0.40 mg/L and 1.00 mg/L, total coliforms ranged from undetectable level to 16.1 most probable number (MPN)/ 100 mL. Keywords: drinking water; treatment plant; distribution network 602 Qaiser, Asma, Khan, Hashmi Introduction Clean drinking water is a precursor for a healthy life and a basic human right. More than a billion people in the developing world lack access to drinking water (IHRO, 2007). South Asia is one of the most rapidly developing regions of the world. Increasing population size and industrial activity has resulted in es calated rates of water scarcity and pollution. Water in South Asia may no longer be thought to represent natural water quality; it shows impact of different types of human activities practically in every part of the sub -continent (Subramanian, 2004) . Fourteen to thirty thousand people, mostly young children and the elderly, die everyday from water related diseases globally (IHRO, 2007). While in 2007, 3 billion people from South Asia lacked proper sanitation and access to clean water (GWP, 2007). With a considerable amount of water wasted and a large proportion used for irrigation, only a tiny portion, 3% of Pakistan’s sweet water reserves, is used for household purposes and drinking. Therefore, the debate about access to water in Pakistan is dominated by i rrigation disputes, mega -projects of dams and canals, and climate change. The focus is on water for agriculture rather than for people (Nils, 2005). Population growth, rapid urbanization and industrialization, are imposing growing demands and pressure on water-resource, which is already deficient. The future, therefore, is likely to be dominated by increasing pressure on water, both driven by the increasing population and rising urbanization. Scarcity, rising demands and competition for water resources has lead to severe misuse of water resources, while the water quality and the environment worsen. In the sectors of urban and rural water supply, the pace of development has not kept up with the need, whereby significant proportions of the population remain deprived of the benefit of clean water supply and sanitation facilities, resulting in a large cost to the nation in terms of people’s health [h]. Results of various investigations provide evidence that most of the drinking -water supplies in both urban and rural areas of Pakistan are faecally contaminated. The poor bacteriological quality of drinking-water has frequently resulted in high incidence of waterborne diseases (Aziz, 2005) . Discharging untreated sewage and chemical wastes directly into rivers, lake s and drains has become a customary practice . Prevalence of waterborne diseases in Pakistan is mainly due to contamination of drinking water with municipal sewage and industrial waste at different points of the water distribution network, lack of water dis infection practices and water quality monitoring at treatment plants. Subsequently, Pakistan’s water quality ranks as 80 th out of 122 nations (UNESCO, 2000) and a majority of the population is exposed to the hazard of drinking unsafe and polluted water (Nils, 2005). Islamabad, the first planned city of Pakistan, is the federal capital as well. Unfortunately, the drinking water quality in most parts of the city is excruciating. A survey carried out by the NIH (2004) revealed that 75% of water in Islamabad is unsafe for human consumption (WB-CWRAS, 2005). The water supply pipes in the distribution network are worn out. In Pakistan, drinking water supply lines and open sewage drains in the streets are laid side by side. As a result, water is Pakistan Engineering Congress, 71st Annual Session Proceedings 603 frequently conta minated when pipes erode (WWF Pakistan, 2010) . Pipe water in Pakistan is contaminated; either because of leakages with all sorts of bacteria or due to geological conditions and insufficient purification; with abnormally high levels of arsenic and elevated fluoride (Nils, 2005). Due to these factors, the water reaching the end consumer is almost always below the standards set up by the National Drinking Water Policy of Pakistan. Shortage of qualified manpower and funds has lead to the derisory provision of water and sanitation services. The gap is further enlarged by the lack of unambiguous definition of responsibilities, work plans and targets, and ineffective coordination and communication between federal, provincial and local administrative entities (Haas et al., 1983). Taking into consideration the worsening water quality in Pakistan, especially in the rapidly growing urban areas, the study was set upon the monitoring of the water distribution network of Islamabad for chemical, physical and microbiologica l water quality. Samples were analyzed for physico-chemical indicators (turbidity, total chlorine, free chlorine residual, total dissolved solids (TDS) and conductivity) and bacterial indicators (total and faecal coliform). Materials and Methods Twenty four samples were collected from different locations of each sector; F – 8 and E-7, during March 2008. From each sector, water samples were collected from the main water source (filtration plants) and consumer ends covering seven residential houses receiving w ater through city pipelines. The collected samples were analyzed for chlorine residual, (MPN: total coliform and faecal coliform), spread plate count as per Standard Methods (APHA, 2005) (Collins et al., 1985). Physical and chemical parameters such as pH, turbidity, TDS and residual chlorine were analyzed from the samples. Total Coliform and Faecal Coliform test were also performed, as per standard methods (APHA, 2005) (Collins et al., 1985) (US-EPA, 1978), to check the microbiological quality of the water. Results and discussion Water quality characteristics Various physical and chemical parameters were analyzed to evaluate water quality of the samples collected. Temperature Water temperature is an important parameter because it is a critical factor in determining the growth of the microorganisms (Ramteke et al. , 1992) . Bacterial growth rates, decay of disinfection residual, corrosion rates and even distribution hydraulics are all affected by water temperature (Kelin et al., 2005). Temperature also affects the dissolved oxygen (DO) level in a water body. DO is critical for the survival of aquatic organisms for aerobic respiration. Temperature of the water samples collected was recorded at the time of sampling. The temperatures of water samples from the sect or F -8 ranged from 19.6°C (at Station # F8 -8) to 22.6°C (at Station # F8-3), as mentioned in Table 1. Water temperature of samples from sector 604 Qaiser, Asma, Khan, Hashmi E-7 ranged from 20.4°C (at Station # E7 -4) to 21.7°C (at Station # E7 -2), as per Table 2 . The temperatures of th e water samples tested were well above the 12°C limit of the WHO. Figure 1 shows temperature obtained at different sampling points of sectors F-8 and E-7. Figure 1: Comparison of average values of Temperature at different sampling stations of sectors F-8 and E-7. pH The pH value measured for the F-8 water samples varies from 6.96 to 7.48 (at Station # F8-2 and F8-5), respectively. On the other hand pH measured for the E -7 water samples varies from 7.26 to 7.65 (at Station # E7-1 and E7-6 respectively), as shown in Figure 2. All the values are well within the desirable pH range 6.5 –8.5 set by the WHO (NSDWQ, 2008). Figure 2 shows pH obtained at different sampling points of sectors F-8 and E-7. Figure 2: Comparison of average values of pH at different sampling stations of sectors F-8 and E-7. Conductivity The value of conductivity varied from 325 S/cm (at Station # F8 -6) to 548 S/cm (at Station # F8 -2) of the sector F -8, as evident from Table 1. In the E -7, it Pakistan Engineering Congress, 71st Annual Session Proceedings 605 varies from 328 to 339 S/cm at Station # E7-7 and E7-2 respectively, as given in Table-2. There is a relationship between TDS and conductivity. As the concentration of dissolved salts (usually salts of sodium, calcium and magnesium, bicarbonate, chloride, and sulphate) increases in water, electri cal conductivity increases (Kelin et al., 2005). The electrical conductivity is higher for water that has more dissolved ionic species. TDS The TDS concentration is considered a secondary drinking water standard, since it is not a health hazard. The prese nce of high levels of TDS in water may be objectionable to consumers owing to the resulting taste and to excessive scaling in water pipes, heaters, boilers, and household appliances. However, it may also indicate elevated levels of ions that do pose a heal th concern, such as aluminium, arsenic, copper, lead, nitrate, and others. Water with extremely low concentrations of TDS may also be unacceptable to consumers because of its flat, insipid taste; it is also often corrosive to water -supply systems. The TDS values of the samples from sector F-8, as evidence from Figure 3, ranged from 156.0 mg/L (at Station # F8-7) to 268.0 mg/L (at Station # F8-3). Whereas TDS values of the E-7 samples ranged from 157.4 to 163.2 mg/L at Station # E7 -5 and E7-2 as evident from Table 2. Figure 3 shows concentration of Total Dissolved Solids obtained at different sampling points of sectors F-8 and E-7. Water containing TDS concentrations below 1000 mg/litre is usually acceptable to consumers, although acceptability may vary accor ding to circumstances (WHO, 2003). The United States Environmental Protection Agency recommends treatment when TDS concentrations exceed 500 mg/L or 500 parts per million (ppm) (US-EPA, 1978). Figure 3: Comparison of average values of Total Dissolved Solids at different sampling stations of sectors F-8 and E-7. 606 Qaiser, Asma, Khan, Hashmi Turbidity Deterioration in drinking water quality in distribution networks is probably due to an increase in microbial numbers, an elevated concentration of iron or increased turbidity, all of wh ich affect taste, odour, and colour in the drinking water. Turbidity can provide shelter for opportunistic microorganisms and pathogens. Hence, waters with high turbidity, from organic sources, also give rise to a substantial chlorine demand for disinfecti on purposes. This could result in reductions in the free chlorine residual in distribution systems as protection against possible recontamination. Therefore, increased pre -chlorination dosage requirements are strongly correlated with increases in turbidity . Increase in turbidity resulted in increase of coliform count. Haas et al. (1983) noted that increased values of pH, temperature, and turbidity were associated with increased concentrations of microorganisms . These findings are also in line with the study conducted by Parent et al. (1996) who studied the control of coliform growth in drinking water distribution systems. In sector F-8, turbidity values were within the highest desirable level values of WHO, i.e., 5 NTU (NSDWQ, 2008), and ranged from 1.30 (a t Station # F8 -2) to 4.46 NTU (at Station # F8 -5), as per Table 1 . In sector F -7, the turbidity value ranged from the lowest value of 2.70 NTU (at Station # E7-7) to the highest value of 8.15 NTU (at Station # E7 -8), as reported in Table 2 . Figure 4 shows the level of turbidity found at different sampling points of sectors F -8 and E -7.Similar results were also reported earlier in a study conducted by the National Water Quality Program, PCRWR (2005), which revealed the range of turbidity from 1.10 to 6.40 NTU (PCRWR, 2005). Figure 4: Comparison of average values of Turbidity at different sampling stations of sectors F-8 and E-7. Chlorine residual In sector F -8, the value of total chlorine observed varied from the lowest value of 0.14 mg/L (at Station # F8 -2) to the highest value of 0.21 mg/L (at two Pakistan Engineering Congress, 71st Annual Session Proceedings 607 stations Station # F8-1 and F8-7) as mentioned in Table 1. In sector E -7, the value of total chlorine varied from 0.40 to 1.00 mg/L at Station # E7-2 and Station # E7-6 respectively, as evident from Table 2 . Fr ee chlorine is the most effective residual disinfectant and may serve as a marker or flag in the distribution network (Olivieri et al., 1986). The largest value of monochloramines, in sector F -8, was recorded as 0.12 ppm (at Station # F8-1), the lowest value was 0.06 ppm at three stations, ( Station # F8-2, F8-4 and F8-7), as per Table 1. Whereas, in sector E-7, as reported in Table 2, the highest value is 0.25 ppm at two stations ( Station # E7 -1 and E7-6) and the lowest value is 0.12 ppm (at Station # E7-7). The largest value of dichloramines, in sector F-8, was recorded as 0.07 ppm (at Station # F8-5), the lowest value was 0.03 ppm (at Station # F8-2), as per Table 1. Whereas, in sector E-7, the highest value is 0.22 ppm (at Station # E7 -1) and the lowest value is 0.05 ppm (at Station # E7 -6), as mentioned in Table 2. Figure 5 shows concentration of free chlorine obtained at different sampling points of sectors F -8 and E -7. Developing countries, like Pakistan, usually have an inadequate water distribution s ystem; due to which the probability of recontamination is very high in both urban and rural areas. The existence of a disinfectant residual is especially important in such regions (Aziz, 2005). Greater concentration of residual chlorine means there is less er microbial contamination. Hence, chlorine residuals of drinking water are incredible indicators of the microbial quality of water in distribution networks (Lienyao et al., 2004). The presence of any disinfectant residual reduces the microorganism level a nd frequency of occurrence at the consumer’s tap (Olivieri et al. , 1986) . Residual chlorine concentrations decline rapidly due to repeated contamination in the distribution system. Since re-chlorination is not practiced, it is difficult to neutralize secondary microbiological contamination of drinking water in the distribution network. Figure 5: Comparison of average values of free chlorine at different sampling stations of sectors F-8 and E-7. 608 Qaiser, Asma, Khan, Hashmi Microbiological Analysis The function of SPC bacteria in p otable water is of high importance. SPC count is more appropriate for examine microorganisms in potable water than the coliform index (Geldreich et al. , 1972) (Muller, 1977) . In SPC technique nutrient agar was used as a growth medium and the results were f ound in CFU/mL. The total viable count obtained was higher in the sector F-8 as compared to the sector E- 7. The viable count obtained was as low as 43 CFU/mL (at Station # F8 -3) to the highest value of 90 CFU/mL (at Station # F8 -6) in the sector F -8, as pe r Table 1. Whereas, in the sector E-7, viable count was below countable range of 30 CFU/ml at all the stations except at station # E7 -6 i.e. 185 CFU/ml which might be due to poor hygienic condition of water storage tank of consumer House # 5. The water samples collected from the sector E -7 revealed higher counts indicating greater contamination even though the concentration of chlorine was higher in the drinking water. As the chlorine concentration decreases, microbial count increases. Cardenas et al. (1993) reported that people in Colombia drinking un-chlorinated water were at increased risk of contracting cholera and diarrhoea with prevalence odds ratios at 5.7 and 3.3, respectively (Cardinas et al., 1993). Figure 6: Comparison of average values of SPC counts at different sampling stations of sectors F-8 and E-7. Most Probable Number The presence of coliform organisms indicates the biological contamination of drinking water (Le Chevallier et al., 1991). It is not necessary to analyse drinking water for all pathogens. Escherichia coli are found in all mammal faeces but it does not multiply significantly in the environment. Hence, it is the best biological drinking water indictor for public health importance (Edberg et al. , 2000) . To determine the presence of total coliform and faecal coliform in drinking water samples, the MPN test was conducted. The samples were run in triplicate. Water samples from eight different water stations of Sectors F -8 and E -7 were inoculated Pakistan Engineering Congress, 71st Annual Session Proceedings 609 into LTB tubes. It is a presumptive t est for coliform. Evaluation of data obtained revealed that samples collected from the Sector F-8 station were more contaminated with faecal coliform than those obtained from sampling points of the E -7 sections. As evident from Table 1, in sector F -8, the value of MPN/ 100 mL for total coliform was 2.2 and probability ranged from 0 to 3 at all sampling stations except for Station # F8 -2 and Station # F8 -3 where MPN/100 mL was 2.2 and probability ranged from 0.26 to 8.1 (sector F -8). In the sector E-7, the value of MPN/100 mL for total coliform was found be less than 1.1 and probability ranged from 0 to 3.0 for all Stations except for Station E7 -6 where it was 16.1 and the probability ranged from 5.9-36.8. Figure 6 shows SPC of bacteria found at different sam pling points of sectors F -8 and E -7. In most developing nations, chlorine residuals are the only final barrier which does not allow microbial degradation of the water quality. The common regulation that demands a “detectable” disinfectant residual may not provide effective consumer protection against microbial contamination. A chloramines residual, instead of free chlorine, may significantly weaken this final barrier against pathogen intrusions (Propato et al. , 2004) . In a study, it was observed that, as th e distance increases from the water reservoir, residual chlorine concentration was significantly reduced at the consumer end causing microbial contaminants to recover to very high levels. Three typical water treatment plants in a northern city (City T) of China and their corresponding distribution systems were investigated. The HPC in distribution systems increased significantly with the decrease of residual chlorine (Lu et al. , 2005) . Furthermore, in Mexico City, bacteriological contamination increased by 26% from the point of treatment to the consumer’s tap (Gaytan et al., 1997). Drinking water samples of the sector E -7 were less contaminated compared to sector F -8. The results for sector F -8 show lower levels of residual chlorine resulting in high faeca l coliform counts at station F8 -2 and F8 -3 and high levels of SPC counts at all stations. However, the results of sector E -7 show a higher level of residual chlorine at all sampling stations with no contamination of pathogenic microorganisms except at E -7-6 which might be due to poor hygienic condition of over head reservoir or due to mixing of sewage water also resulting in higher SPC. These results are not in confirmation to the WHO bacteriological water quality standards of treated water entering the dis tribution system, which recommends 0/100 mL for E. coli and total coliform bacteria (WHO, 2003); hence, water is unfit for human consumption. Water quality decay in the distribution network can be caused by properties of pipeline materials, hydraulic condi tions, biofilm thickness, excessive network leakages, corrosion of parts, and intermittent service (Lou et al., 2007) (Lee et al. , 2005) . Current monitoring systems are only for random testing and cannot record pollution level. Chlorination is an appropria te tool to limit coliforms much more easily than the total heterotrophic bacterial biomass. However, in all cases, biofilm -associated bacteria are more difficult to kill than suspended bacteria because of chlorine consumption by the pipe material and because of a diffusion -limited reaction between chlorine and the biofilm (Hashmi et al., 2009). Hence, the water distribution systems were not capable of maintaining high water quality from the water treatment facilities to the end-user. 610 Qaiser, Asma, Khan, Hashmi Conclusions This stud y was aimed at assessing the quality of drinking water of Islamabad, to relate the chlorine dosage with microbial contamination, due to the deteriorating water quality. It is anticipated that the monitoring results would lead to remedial measures for impro ving the current drinking water quality situation in the city. From the analysis of overall water quality, it can be concluded that: The samples were collected from eight different sampling points from the water distribution network of two sectors, sect or F-8 and sector E – 7. Total residual chlorine varied largely among different sampling points ranging from lowest value of 0.09 mg/l at sector F -8 to the highest value of 0.78 mg/l at sector E-7. At all the stations, of sector F-8 and E-7, the MPN was found less than 1.1 except at Station # F8 -2 and F8-3, where the lowest MPN of 2.2, and Station # E7-6, where the count of 16.1 was observed. Apart from the three stations mentioned above, the results for the faecal coliform test were highly satisf actory as the number of coliforms were below the detectable limit. Station # E7 -6 was found to be the most contaminated due to cross connection of drinking water with domestic wastewater. Physiochemical water quality parameters such as pH, temperature, electrical conductivity, total dissolved solids were found within the permissible limits of WHO standards. Microbial count was found to be inversely proportional with chlorine residual whereas a direct relationship was observed with turbidity. As the chlorine concentration increased, microbial counts decreased while increase in turbidity resulted in increase in microbial contamination. Based upon the results of this study it is recommended that regular monitoring of residual chlorine concentration and total coliforms in the water distribution system should be carried out to ensure that the chlorine residual of 0.2–0.5 mg/l is available at the consumer end. The civic agencies, like WASA, CDA and RDA, should take immediate action in this regard. The g overnment, NGO’s and civic agencies have to work together to provide clean drinking water, that meets the standards set by NEQS, to the people. Acknowledgements We gratefully acknowledge the financial support of Higher Education Commission (Project No. 20 -874/HEC/R&D/07/379), Pakistan to carry out this research and the support of Capital Development Authority (CDA), Islamabad. Pakistan Engineering Congress, 71st Annual Session Proceedings 611 References APHA. (2005). Standard methods for the examination of water and wastewater. Washington: American Public Health Association. Aziz, J. A. (2005). Management of source and drinking -water quality in Pakistan. Eastern Mediterranean Health Journal . 11(September 2005):5 -6. Retrieved from: http://www.emro.who.int/publications/emhj/1105_6/Artical26.htm Cardenas, V., Saad, C., Varona, M. and Linero, M. (1993). Waterborne cholera in Riohacha, Colombia, 1992. Bulletin of the Pan American Health Organization. 27(4):313-330. Collins, C.H. and Lyne, P.M. (1985). Microbiological methods. Butterworth & Co Publishers Ltd, London. Edberg, S. C., Rice, E. W., Karlin, R. J. and Allen, M. J. (2000). Escherichia coli: the best biological drinking water indicator for public health protection. Department of Laboratory Medicine, Yale University School of Medicine, New Haven, CT, USA. Symposium Series Society for Applied Microbiology . (29):106S – 116S. Egorov, A., Ford, T., Tereschenko, A., Drizhd, N., Segedevich, I. and Fourman, V. (2002). Deterioration of drinking water quality in the distribution system and gastrointestinal morbidity in a Russian city. International Journal of Environmental Health Research . 12(3):221 -233. doi:10.1080/09603/202/000000989. Farooq, S., Hashmi, I., Qazi, I. A., Qaiser, S. and Rasheed, S. (2008). Monitoring of coliforms and chlorine residual in water distribution network of Rawalpindi, Pakistan. Environmental Monitoring and Assessment . 140(1 – 3):399-347. (Gaytan et al. , 1997) Gaytan, M., Castro, T., Bonilla, P., Lugo, A. and Vilaclara, G. (1997). Preliminary study of selected drinking water samples in Mexico City. Revista Internacional de Contaminacion Ambiental. 13(2):73-78. Geldreich, E. E., Nash, H. D., Reasoner, D. J., and Taylor, R. H. (1972). The necessity of cont rolling bacterial populations in potable waters; community water supply. Journal of the American Water Works Association. 64:596-602. GWP, Global Water Partnership -South Asia. (2007). Retrieved from: http://www.gwpforum.org Haas, C. N., Meyer, M. A. and Paller, M. S. (1983). Microbial alterations in water distribution systems and their relationship to physical –chemical characteristics. Journal of the American Water Works Association.75:475. Hashmi, I., Farooq, S. and Qaiser, S. (2009). Incidence of fecal contamination within a public drinking water supply in Ratta Amral, Rawalpindi. Desalination and water treatment. 11(2009):1-8. 612 Qaiser, Asma, Khan, Hashmi International Human Rights Observer (IHRO). (2007). Coping with Water Scarcity. http://ihro.org.pk/downloads/WATERFORLIFE.pdf Johnson, P., Graham, N.J.D. and Wilson, M. (1997). Predictive Chlorine Dosing: A New Paradigm. Water and Environment Journal. 11(6):413-422. Kelin, H., Yuang, H.F., Hong, L. and Robert, W.E. (2005). Spatial variability of shallow ground water level, electrical conductivity and nitrate concentration and risk assessment of nitrate contamination in North China plain. Environment International. 31:896-903. Kitazawa, H. (2006). Keeping residual chlorine and decreasing unpleasant odor caused by disinfection of tap water. Water Supply. 6(2):193-199. Le Chevallier, M. W., Norton, W. D. and Lee, R. G. (1991). Giardia and Cryptosporidium spp. in filtered drinking water supplies. Applied and Environmental Microbiology. 57(9):2617-2621. Lee, E. J. and Schwab, K. J. (2005). Deficiencies in drinking water distribution systems in developing countries. Journal of Water and Health . 3(2):109-127. NSDWQ, National Standards for Drinking Water Quality. (2008). Pakistan Environment Protection Agency. http://www.environment.gov.pk/act- rules/DWQStd-MAY2007.pdf Lienyao, L., Chungsyi ng, L., & Shyang -Lai, K. (2004). Spatial diversity of chlorine residual in a drinking water distribution system. Journal of Environmental Engineering. 130:1263-1268. Lou, J. C. and Han, J. Y. (2007). Assessing water quality of drinking water distribution system in the South Taiwan. Environmental Monitoring and Assessment. 134(1–3):343-354. Lu, W. and Zhang, X. J. (2005). Factors affecting bacterial growth in drinking water distribution system. Biomed Environ Sci. 2005 Apr. 18(2):137-40. Department of Environmental Science and Engineering, Tsinghua University, Beijing. Muller, G. (1977). Bacterial indicators and standards f or water quality in the Federal Republic of Germany. In A. W. Hoadley & B. J. Dutka (Eds.), Bacterial indicators/hazards associated with water. 159-167. Philadelphia: American Society for Testing and Materials. Nils Rosemann. (2005). Drinking water cris is in Pakistan and the issue of bottled water – The case of Nestlé’s ‘Pure Life’ . http://www.alliancesud.ch/en/policy/water/downloads/nestle-pakistan.pdf Olivieri, V. P., Snead, M. C., Kruse, C. W. and Kawata, K. (1986). Stability and effectiveness of chlorine disinfectants in water distribution systems. Environmental Health Perspectives. 69:15-29. Pakistan Engineering Congress, 71st Annual Session Proceedings 613 PCRWR. Pakistan Council of Research and Water Resources. (2005). National Water Quality Monitoring Programme, Report 2004, Islamabad. Propato, M. and Uber, J. G. (2004). Vulnerability of water distribution systems to pathogen intrusion: how effective is a disinfectant residual? Department of Civil and Environmental Engi neering, University of Cincinnati, Cincinnati, Ohio 45221, USA. Environmental Science & Technology. 38(13):3713-22. Ramteke, P. W., Bhattacharjee, J. W., Pathak, S. P., & Kaira, N. (1992). Evaluation of coliforms as indicators of water quality in India. Journal of Applied Bacteriology. 72(4):352-356. Subramanian, V. (2004). Water Quality in South Asia. Asian Journal of Water Environment and Pollution. 1(1-2(2004)):41-54. http://iospress.metapress.com/content/j765b91l5wuwgjxg/ UNESCO. (2000). Water quality indicator values in selected countries. UNSP, The United Nations System in Pakistan. Water—A Vital Source of Life, Islamabad. (2003). 63. US-EPA. (1978). Methods for the chemical analysis of water and wastes. US – EPA-625/6-74-003. Washington, DC:Office of Technology Transfer. WB-CWRAS, The World Bank. (2005). Pakistan country water resources assistance strategy water economy: Running dry. Washington, DC: WB – CWRAS. World Health Organization (WHO). (2003). Acceptability aspects. In Guidelines for Drinking Water Quality ed . Chapter 10. World Health Organization. Geneva. WWF, Pakistan. (2010). Water Pollution Factsheet. Retrieved from: http://www.wwfpak.org/factsheets_wps.php 614 Qaiser, Asma, Khan, Hashmi Table 1: Mean value of Microbial and Chemical Analysis of Water Samples Collected from Sector F-8 Water Parameters Station Numbers F8-1 F8-2 F8-3 F8-4 F8-5 F8-6 F8-7 F8-8 Station Name 5 MGR H1 H2 H3 H4 H5 H6 H7 Temp (°C) 19.2-20.2 21.9-23 21.4-23.5 20.3-21.2 20.1-21.5 19.3-20.3 19.8-21 18-20.8 20 22.4 22.6 20.6 21 19.7 21 19.6 PH 6.7-7.6 7.26-7.49 6.94-6.99 6.96-7.30 7.06-7.29 7.25-7.68 7.17-7.38 6.69-7.04 7.15 7.4 6.96 7.12 7.2 7.48 7.28 6.81 TDS (mg/l) 155-167.8 234-270 242-309 157-164 156.4-162.4 156-158.1 154.8-156.5 252-261 160 248 268 159.6 158.4 157.1 156 258 Conductivity (µS/cm) 323-335 482-538 486-635 326-332 325-328 325-327 324-326 518-538 328 505 548 329 326 326 325 528 Turbidity (NTU) 2.97-4.21 0.88-1.61 1.73-3.63 3.46-3.91 3.73-5.68 3.62-3.89 3.57-3.7 1.46-5.98 3.74 1.3 2.58 3.69 4.46 3.78 3.62 3.14 Total Chlorine (ppm) 0.1-0.35 0.1-0.18 0.12-0.23 0.13-0.24 0.13-0.25 0.13-0.25 0.13-0.25 0.08-0.27 0.21 0.14 0.17 0.17 0.2 0.18 0.21 0.15 Free chlorine (ppm) 0.08-0.22 0.05-0.12 0.06-0.12 0.08-0.14 0.08-0.19 0.07-0.14 0.07-0.11 0.06-0.11 0.14 0.09 0.13 0.11 0.13 0.11 0.09 0.09 Monochloramine (ppm) 0.07-0.18 0.04-0.07 0.04-0.1 0.06-0.07 0.06-0.18 0.06-0.08 0.06-0.07 0.05-0.09 0.12 0.06 0.07 0.06 0.1 0.07 0.06 0.07 Dichloramines (ppm) 0.04-0.05 0.02-0.04 0.05-0.06 0.04-0.08 0.05-0.11 0.04-0.06 0.05-0.06 0.04-0.06 0.05 0.03 0.06 0.06 0.07 0.05 0.05 0.05 Total Coliform (MPN index/ 100ml) <1.1 2.2 2.2 <1.1 <1.1 <1.1 <1.1 <1.1 Faecal Coliform <1.1 2.2 2.2 <1.1 <1.1 <1.1 <1.1 <1.1 Range 95% Probability 0-3.0 0.26- 8.1 0.26- 8.1 0-3.0 0-3.0 0-3.0 0-3.0 0-3.0 SPC (HPC) (CFU /ml) 52 76 43 48 53 90 43 53 NTU = Nephlometric turbidity units, CFU = Colony Forming Units, MGR = Million Gallon Reservoir, H (1, 2, 3, 4, 5, 6, 7) = Consumer Houses Note: Top reading in each cell refers to range and bottom reading to the mean value * Based on mean of three replicates (Dated: 25/03/08, 27/03/08 and 31/03/08). Pakistan Engineering Congress, 71st Annual Session Proceedings 615 Table 2: Mean value of Microbial and Chemical Analysis of Water Samples Collected from Sector E-7 Water Parameters Station Numbers E7-1 E7-2 E7-3 E7-4 E7-5 E7-6 E7-7 E7-8 Station Name 5 MGR H1 H2 H3 H4 H5 H6 H7 Temp (°C) 18.3-23.4 19.7-25.5 17.7-25 17.3-24.8 17.9-24.8 17.9-23.8 17.4-23.8 17.9-23.3 20.9 21.7 20.6 20.4 20.7 20.8 21.2 20.6 pH 6.96-7.53 7.19-7.69 7.3-7.69 7.14-7.65 7.14-7.61 7.30-7.73 7.46-7.83 7.10-7.63 7.26 7.4 7.47 7.34 7.3 7.52 7.65 7.31 TDS (mg/l) 156.3-159.5 161-167 156-160.7 155.6-160.5 154.9-160 156.6- 163.7 158.3- 160.7 155.4- 159.9 158.3 163.2 158.7 108.3 157.4 160 160 158.1 Conductivity(µS/cm) 331-325 334-347 325-334 322-334.4 323-332 321-340 330-333 321-331 329 339 330 328.8 328 331 332 328 Turbidity (NTU) 6.16-7.54 6.47-8.33 6.10-7.30 6.66-8.41 6.19-7.63 6.40-7.90 1.88-3.80 7.5-8.75 6.75 7.35 6.53 7.57 7 6.89 2.7 8.15 Total Chlorine (ppm) 0.7 0.4 0.55 0.52 0.51 1 0.46 0.62 Free chlorine (ppm) 0.47-0.73 0.22-0.39 0.31-0.61 0.41-0.50 0.4-0.51 0.65-1.00 0.09-0.16 0.45-0.67 0.61 0.32 0.49 0.46 0.44 0.78 0.12 0.53 Monochloramine (ppm) 0.18-0.40 0.15-0.2 0.14-0.34 0.16-0.26 0.17-0.33 0.18-0.35 0.09-0.15 0.15-0.19 0.25 0.17 0.22 0.19 0.23 0.25 0.12 0.17 Dichloramines (ppm) 0.10-0.38 0.05-0.18 0.09-0.13 0.06-0.15 0.07-0.28 0.06-0.21 0.04-0.07 0.13-0.17 0.22 0.11 0.11 0.1 0.15 0.13 0.05 0.15 Total Coliform (MPN index/100ml) <1.1 <1.1 <1.1 <1.1 <1.1 16.1 <1.1 <1.1 Faecal Coliform (MPN index/100ml) <1.1 <1.1 <1.1 <1.1 <1.1 16.1 <1.1 <1.1 Range 95% Probability 0-3.0 0-3.0 0-3.0 0-3.0 0-3.0 5.9-36.8 0-3.0 0-3.0 SPC (HPC) (CFU /ml) 7 7 4 5 8 6 185 8 NTU = Nephlometric turbidity units, CFU = Colony Forming Units, MGR = Million Gallon Reservoir, H (1, 2, 3, 4, 5, 6, 7) = Consumer Houses Note: Top reading in each cell refers to range and bottom reading to the mean value * Based on mean of three replicates (Dated: 25/03/08, 27/03/08 and 31/03/08) 616 Qaiser, Asma, Khan, Hashmi

Filename: DRINKING-WATER-QUALITY-MONITORING-WITHIN-A-DISTRIBUTION-NETW.pdf
File Type: pdf
File Size: 480 KB
Categories: 0071st Annual Issue 2011
Author: Imran Hashmi, M. Talal Ali Khan, Sara Qaiser, Syeda Asma
Downloads: 1